Mileva 33-320F2021-07-27T11:16:48+00:00

Mileva 33-320F

Mileva 33-320F

24/7 monitoring system

Mileva 33-320F is the latest model of Optical Gas Imaging for micro-leaks detection of Volatile Organic Compounds (VOC’s) and hydrocarbon (HxCx) gases from long distances.

Spectrally optimized cooled detector of 320 x 256 pixels improves the minimum detectable leak rate of VOCs.

Mileva 33-320F Specifications2021-07-15T13:09:26+00:00
Base Specifications
FPACooled 320 x 256 px
Pixel Pitch30 μm
NETD<10mK @ +50ºC
LensesN: 12ºx9º | M: 18ºx13º
Accuracy± 1ºC (from 0ºC to 70ºC Scene Temp.)
Data ProtocolGigE
Power12 watts
Weight13 kg
Size161x179x385 mm
Operation Temperature-15ºC to +40ºC
Storage Temperature-40ºC to +71ºC
Features under demand
ScanningPan & Tilt
SMART ModelRequest for more information
Non-ATEX Housing
Ingress ProtectionIP65
Weight4,9 kg
Size110 x 135 x 300 mm
Certifications
Ingress ProtectionEN 60529 (IP66/IP67)
RatingII 2 G Ex db op pr IIC T6 Gb -40°C ≤ Tamb ≤ +60°C
II 2 D Ex tb IIIC T85°C Db -40°C ≤ Tamb ≤ +60°C
ATEX StandardsEN 60079-0:2012; EN 60079-1:2014
EN 60079-28:2015; EN 60079-31:2014
IECEX StandardsIEC 60079-0:2011; IEC 60079-1:2014-06
IEC 60079-28:2015; IEC 60079-31:2013
EMCEN 61000-6-3:2007
EN 50130-4:1995 + A1:1998 + A2:2003
LVDEN 60950-1:2006 + A11:2009
RoHS2011/65/EU
WEEE2012/19/EU
EPAEPA OOOOa COMPLIANCE
Gases detected by Mileva 33 and 33F2021-06-23T14:23:38+00:00
Volatile Organic Compounds (VOC’s)
MethanolEthanol
EthylbenzeneHeptane
MethanePentane
MEKMIBK
Benzene1-Pentene
TolueneXylene
EthaneIsoprene
PropaneEthylene
PropyleneButane
OctaneHexane
On-field gas detection performance2020-07-20T10:03:07+00:00

The following table shows the gas detection capabilities of the SENSIA OGI’s under real scenarios conditions.

CarolineMileva 33
Minimum Methane mass flow rate for detectionDetection distanceDetection distance
0,3 g/s50 m125 m
0,5 g/s100 m250 m

This table specifies the minimum mass flow rate, for methane as the reference gas, that can be detected by each technology from a certain distance.

RedLook is implemented in SENSIA’s line of fixed systems for 24/7 monitoring. This comprehensive monitoring system presents innovative capabilities assembled under a single control software.

Mileva 33-320F performance lets RedLook to enable exhaustive monitoring and real-time alerting. Our software is highly versatile, allowing to configure several Regions of Interest (RoI) within the area to be monitored. And to each one of them, any functionality can be assigned, granting a total and safe surveillance of the installation.

MAIN FEATURES AND SPECIFICATIONS
Let us find a solution

Rely on our expertise and receive technical support.

Let our products meet your ideas and reduce time-to-market.

Go to Top